An X-ray computed tomography demonstrator using a CZT solid-state detector

T. Claesson, A. Kerek, J. Molnár, D. Novák

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

A demonstrator of Computed Tomography (CT) has been designed and built for educational purposes. The system is based on a solid-state CdZnTe detector and a standard PC. The mechanics of the system is controlled and data is acquired by programs written in LabVIEW. CT images are reconstructed using MATLAB programs.

Original languageEnglish
Pages (from-to)202-208
Number of pages7
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume487
Issue number1-2
DOIs
Publication statusPublished - Jul 11 2002

Fingerprint

Tomography
tomography
Detectors
solid state
X rays
detectors
MATLAB
Mechanics
x rays

Keywords

  • CdZnTe detector
  • CT
  • Demonstrator

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

@article{4ea462714928492993ee1de6413665dd,
title = "An X-ray computed tomography demonstrator using a CZT solid-state detector",
abstract = "A demonstrator of Computed Tomography (CT) has been designed and built for educational purposes. The system is based on a solid-state CdZnTe detector and a standard PC. The mechanics of the system is controlled and data is acquired by programs written in LabVIEW. CT images are reconstructed using MATLAB programs.",
keywords = "CdZnTe detector, CT, Demonstrator",
author = "T. Claesson and A. Kerek and J. Moln{\'a}r and D. Nov{\'a}k",
year = "2002",
month = "7",
day = "11",
doi = "10.1016/S0168-9002(02)00966-X",
language = "English",
volume = "487",
pages = "202--208",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - An X-ray computed tomography demonstrator using a CZT solid-state detector

AU - Claesson, T.

AU - Kerek, A.

AU - Molnár, J.

AU - Novák, D.

PY - 2002/7/11

Y1 - 2002/7/11

N2 - A demonstrator of Computed Tomography (CT) has been designed and built for educational purposes. The system is based on a solid-state CdZnTe detector and a standard PC. The mechanics of the system is controlled and data is acquired by programs written in LabVIEW. CT images are reconstructed using MATLAB programs.

AB - A demonstrator of Computed Tomography (CT) has been designed and built for educational purposes. The system is based on a solid-state CdZnTe detector and a standard PC. The mechanics of the system is controlled and data is acquired by programs written in LabVIEW. CT images are reconstructed using MATLAB programs.

KW - CdZnTe detector

KW - CT

KW - Demonstrator

UR - http://www.scopus.com/inward/record.url?scp=0037063073&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037063073&partnerID=8YFLogxK

U2 - 10.1016/S0168-9002(02)00966-X

DO - 10.1016/S0168-9002(02)00966-X

M3 - Article

VL - 487

SP - 202

EP - 208

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 1-2

ER -