An improved method for the determination of the neutron fluence in fission power reactors based on the 93Nb(n,n′)93mNb reaction

I. Szalóki, S. Szegedi, M. Váradi, Cs M. Buczkó, A. Pázsit, F. Divós

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The X-ray fluorescence method was introduced to measure the weight of an Nb monitor used for the neutron fluence measurement via the 93Nb(n,n′)93mNb reaction in a fission reactor. Results were compared with those obtained by γ-spectrometry based on the 93Nb(n,γ) 94Nb reaction. For comparison, the specific activities of 93mNb measured in two different laboratories are also given.

Original languageEnglish
Pages (from-to)523-525
Number of pages3
JournalAnnals of Nuclear Energy
Volume15
Issue number10-11
DOIs
Publication statusPublished - 1988

Fingerprint

Nuclear reactors
X-ray fluorescence
Spectrometry
spectrometry
Neutrons
Fluorescence
X rays
reactor
laboratory
comparison
method

ASJC Scopus subject areas

  • Nuclear Energy and Engineering
  • Waste Management and Disposal

Cite this

An improved method for the determination of the neutron fluence in fission power reactors based on the 93Nb(n,n′)93mNb reaction. / Szalóki, I.; Szegedi, S.; Váradi, M.; Buczkó, Cs M.; Pázsit, A.; Divós, F.

In: Annals of Nuclear Energy, Vol. 15, No. 10-11, 1988, p. 523-525.

Research output: Contribution to journalArticle

Szalóki, I. ; Szegedi, S. ; Váradi, M. ; Buczkó, Cs M. ; Pázsit, A. ; Divós, F. / An improved method for the determination of the neutron fluence in fission power reactors based on the 93Nb(n,n′)93mNb reaction. In: Annals of Nuclear Energy. 1988 ; Vol. 15, No. 10-11. pp. 523-525.
@article{09b345b02c604a4d88067f6504f7b7f8,
title = "An improved method for the determination of the neutron fluence in fission power reactors based on the 93Nb(n,n′)93mNb reaction",
abstract = "The X-ray fluorescence method was introduced to measure the weight of an Nb monitor used for the neutron fluence measurement via the 93Nb(n,n′)93mNb reaction in a fission reactor. Results were compared with those obtained by γ-spectrometry based on the 93Nb(n,γ) 94Nb reaction. For comparison, the specific activities of 93mNb measured in two different laboratories are also given.",
author = "I. Szal{\'o}ki and S. Szegedi and M. V{\'a}radi and Buczk{\'o}, {Cs M.} and A. P{\'a}zsit and F. Div{\'o}s",
year = "1988",
doi = "10.1016/0306-4549(88)90069-2",
language = "English",
volume = "15",
pages = "523--525",
journal = "Annals of Nuclear Energy",
issn = "0306-4549",
publisher = "Elsevier Limited",
number = "10-11",

}

TY - JOUR

T1 - An improved method for the determination of the neutron fluence in fission power reactors based on the 93Nb(n,n′)93mNb reaction

AU - Szalóki, I.

AU - Szegedi, S.

AU - Váradi, M.

AU - Buczkó, Cs M.

AU - Pázsit, A.

AU - Divós, F.

PY - 1988

Y1 - 1988

N2 - The X-ray fluorescence method was introduced to measure the weight of an Nb monitor used for the neutron fluence measurement via the 93Nb(n,n′)93mNb reaction in a fission reactor. Results were compared with those obtained by γ-spectrometry based on the 93Nb(n,γ) 94Nb reaction. For comparison, the specific activities of 93mNb measured in two different laboratories are also given.

AB - The X-ray fluorescence method was introduced to measure the weight of an Nb monitor used for the neutron fluence measurement via the 93Nb(n,n′)93mNb reaction in a fission reactor. Results were compared with those obtained by γ-spectrometry based on the 93Nb(n,γ) 94Nb reaction. For comparison, the specific activities of 93mNb measured in two different laboratories are also given.

UR - http://www.scopus.com/inward/record.url?scp=24544453213&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=24544453213&partnerID=8YFLogxK

U2 - 10.1016/0306-4549(88)90069-2

DO - 10.1016/0306-4549(88)90069-2

M3 - Article

VL - 15

SP - 523

EP - 525

JO - Annals of Nuclear Energy

JF - Annals of Nuclear Energy

SN - 0306-4549

IS - 10-11

ER -