Accurate determination of quantity of material in thin films by Rutherford backscattering spectrometry

C. Jeynes, N. P. Barradas, E. Szilágyi

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

Ion beam analysis (IBA) is a cluster of techniques including Rutherford and non-Rutherford backscattering spectrometry and particle-induced X-ray emission (PIXE). Recently, the ability to treat multiple IBA techniques (including PIXE) self-consistently has been demonstrated. The utility of IBA for accurately depth profiling thin films is critically reviewed. As an important example of IBA, three laboratories have independently measured a silicon sample implanted with a fluence of nominally 5 × 10 15 As/cm 2 at an unprecedented absolute accuracy. Using 1.5 MeV 4He + Rutherford backscattering spectrometry (RBS), each lab has demonstrated a combined standard uncertainty around 1% (coverage factor k = 1) traceable to an Sb-implanted certified reference material through the silicon electronic stopping power. The uncertainty budget shows that this accuracy is dominated by the knowledge of the electronic stopping, but that special care must also be taken to accurately determine the electronic gain of the detection system and other parameters. This RBS method is quite general and can be used routinely to accurately validate ion implanter charge collection systems, to certify SIMS standards, and for other applications. The generality of application of such methods in IBA is emphasized: if RBS and PIXE data are analysed self-consistently then the resulting depth profile inherits the accuracy and depth resolution of RBS and the sensitivity and elemental discrimination of PIXE.

Original languageEnglish
Pages (from-to)6061-6069
Number of pages9
JournalAnalytical Chemistry
Volume84
Issue number14
DOIs
Publication statusPublished - Jul 17 2012

Fingerprint

Rutherford backscattering spectroscopy
Spectrometry
Ion beams
Thin films
X rays
Silicon
Depth profiling
Backscattering
Secondary ion mass spectrometry
Power electronics
Ions
Uncertainty

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Accurate determination of quantity of material in thin films by Rutherford backscattering spectrometry. / Jeynes, C.; Barradas, N. P.; Szilágyi, E.

In: Analytical Chemistry, Vol. 84, No. 14, 17.07.2012, p. 6061-6069.

Research output: Contribution to journalArticle

@article{2c532ac0668e40e8afeb016f77e61eac,
title = "Accurate determination of quantity of material in thin films by Rutherford backscattering spectrometry",
abstract = "Ion beam analysis (IBA) is a cluster of techniques including Rutherford and non-Rutherford backscattering spectrometry and particle-induced X-ray emission (PIXE). Recently, the ability to treat multiple IBA techniques (including PIXE) self-consistently has been demonstrated. The utility of IBA for accurately depth profiling thin films is critically reviewed. As an important example of IBA, three laboratories have independently measured a silicon sample implanted with a fluence of nominally 5 × 10 15 As/cm 2 at an unprecedented absolute accuracy. Using 1.5 MeV 4He + Rutherford backscattering spectrometry (RBS), each lab has demonstrated a combined standard uncertainty around 1{\%} (coverage factor k = 1) traceable to an Sb-implanted certified reference material through the silicon electronic stopping power. The uncertainty budget shows that this accuracy is dominated by the knowledge of the electronic stopping, but that special care must also be taken to accurately determine the electronic gain of the detection system and other parameters. This RBS method is quite general and can be used routinely to accurately validate ion implanter charge collection systems, to certify SIMS standards, and for other applications. The generality of application of such methods in IBA is emphasized: if RBS and PIXE data are analysed self-consistently then the resulting depth profile inherits the accuracy and depth resolution of RBS and the sensitivity and elemental discrimination of PIXE.",
author = "C. Jeynes and Barradas, {N. P.} and E. Szil{\'a}gyi",
year = "2012",
month = "7",
day = "17",
doi = "10.1021/ac300904c",
language = "English",
volume = "84",
pages = "6061--6069",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "14",

}

TY - JOUR

T1 - Accurate determination of quantity of material in thin films by Rutherford backscattering spectrometry

AU - Jeynes, C.

AU - Barradas, N. P.

AU - Szilágyi, E.

PY - 2012/7/17

Y1 - 2012/7/17

N2 - Ion beam analysis (IBA) is a cluster of techniques including Rutherford and non-Rutherford backscattering spectrometry and particle-induced X-ray emission (PIXE). Recently, the ability to treat multiple IBA techniques (including PIXE) self-consistently has been demonstrated. The utility of IBA for accurately depth profiling thin films is critically reviewed. As an important example of IBA, three laboratories have independently measured a silicon sample implanted with a fluence of nominally 5 × 10 15 As/cm 2 at an unprecedented absolute accuracy. Using 1.5 MeV 4He + Rutherford backscattering spectrometry (RBS), each lab has demonstrated a combined standard uncertainty around 1% (coverage factor k = 1) traceable to an Sb-implanted certified reference material through the silicon electronic stopping power. The uncertainty budget shows that this accuracy is dominated by the knowledge of the electronic stopping, but that special care must also be taken to accurately determine the electronic gain of the detection system and other parameters. This RBS method is quite general and can be used routinely to accurately validate ion implanter charge collection systems, to certify SIMS standards, and for other applications. The generality of application of such methods in IBA is emphasized: if RBS and PIXE data are analysed self-consistently then the resulting depth profile inherits the accuracy and depth resolution of RBS and the sensitivity and elemental discrimination of PIXE.

AB - Ion beam analysis (IBA) is a cluster of techniques including Rutherford and non-Rutherford backscattering spectrometry and particle-induced X-ray emission (PIXE). Recently, the ability to treat multiple IBA techniques (including PIXE) self-consistently has been demonstrated. The utility of IBA for accurately depth profiling thin films is critically reviewed. As an important example of IBA, three laboratories have independently measured a silicon sample implanted with a fluence of nominally 5 × 10 15 As/cm 2 at an unprecedented absolute accuracy. Using 1.5 MeV 4He + Rutherford backscattering spectrometry (RBS), each lab has demonstrated a combined standard uncertainty around 1% (coverage factor k = 1) traceable to an Sb-implanted certified reference material through the silicon electronic stopping power. The uncertainty budget shows that this accuracy is dominated by the knowledge of the electronic stopping, but that special care must also be taken to accurately determine the electronic gain of the detection system and other parameters. This RBS method is quite general and can be used routinely to accurately validate ion implanter charge collection systems, to certify SIMS standards, and for other applications. The generality of application of such methods in IBA is emphasized: if RBS and PIXE data are analysed self-consistently then the resulting depth profile inherits the accuracy and depth resolution of RBS and the sensitivity and elemental discrimination of PIXE.

UR - http://www.scopus.com/inward/record.url?scp=84863957489&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863957489&partnerID=8YFLogxK

U2 - 10.1021/ac300904c

DO - 10.1021/ac300904c

M3 - Article

C2 - 22681761

AN - SCOPUS:84863957489

VL - 84

SP - 6061

EP - 6069

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 14