A velocity driven lumped-parameter model of mitral valve blood flow

Lee Waite, Jerry Fine, Gábor Veres, G. Szabó

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

A lumped-parameter model of flow through the mitral valve was developed. The model can use minimally-invasive Doppler ultrasound velocity waveforms as model inputs. The model is based on a previously developed model that was developed and calibrated in porcine trials. We have continued the validation of the model in canine trials with the long term goal of developing a clinically useful diagnostic tool in humans. This velocity driven model is a key step toward development of that tool.

Original languageEnglish
Title of host publication46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009
Pages401-406
Number of pages6
Volume476
Publication statusPublished - 2009
Event46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009 - Milwaukee, WI, United States
Duration: Apr 17 2009Apr 19 2009

Other

Other46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009
CountryUnited States
CityMilwaukee, WI
Period4/17/094/19/09

Fingerprint

Doppler Ultrasonography
Mitral Valve
Canidae
Blood
Swine
Ultrasonics

Keywords

  • Computational fluid dynamics
  • Congestive heart failure
  • Insufficiency
  • Lumped-parameter model
  • Mitral valve

ASJC Scopus subject areas

  • Biotechnology
  • Bioengineering
  • Biomedical Engineering

Cite this

Waite, L., Fine, J., Veres, G., & Szabó, G. (2009). A velocity driven lumped-parameter model of mitral valve blood flow. In 46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009 (Vol. 476, pp. 401-406)

A velocity driven lumped-parameter model of mitral valve blood flow. / Waite, Lee; Fine, Jerry; Veres, Gábor; Szabó, G.

46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009. Vol. 476 2009. p. 401-406.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Waite, L, Fine, J, Veres, G & Szabó, G 2009, A velocity driven lumped-parameter model of mitral valve blood flow. in 46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009. vol. 476, pp. 401-406, 46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009, Milwaukee, WI, United States, 4/17/09.
Waite L, Fine J, Veres G, Szabó G. A velocity driven lumped-parameter model of mitral valve blood flow. In 46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009. Vol. 476. 2009. p. 401-406
Waite, Lee ; Fine, Jerry ; Veres, Gábor ; Szabó, G. / A velocity driven lumped-parameter model of mitral valve blood flow. 46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009. Vol. 476 2009. pp. 401-406
@inproceedings{f218c2e3766a4fbea557836ee96af993,
title = "A velocity driven lumped-parameter model of mitral valve blood flow",
abstract = "A lumped-parameter model of flow through the mitral valve was developed. The model can use minimally-invasive Doppler ultrasound velocity waveforms as model inputs. The model is based on a previously developed model that was developed and calibrated in porcine trials. We have continued the validation of the model in canine trials with the long term goal of developing a clinically useful diagnostic tool in humans. This velocity driven model is a key step toward development of that tool.",
keywords = "Computational fluid dynamics, Congestive heart failure, Insufficiency, Lumped-parameter model, Mitral valve",
author = "Lee Waite and Jerry Fine and G{\'a}bor Veres and G. Szab{\'o}",
year = "2009",
language = "English",
isbn = "9781615671519",
volume = "476",
pages = "401--406",
booktitle = "46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009",

}

TY - GEN

T1 - A velocity driven lumped-parameter model of mitral valve blood flow

AU - Waite, Lee

AU - Fine, Jerry

AU - Veres, Gábor

AU - Szabó, G.

PY - 2009

Y1 - 2009

N2 - A lumped-parameter model of flow through the mitral valve was developed. The model can use minimally-invasive Doppler ultrasound velocity waveforms as model inputs. The model is based on a previously developed model that was developed and calibrated in porcine trials. We have continued the validation of the model in canine trials with the long term goal of developing a clinically useful diagnostic tool in humans. This velocity driven model is a key step toward development of that tool.

AB - A lumped-parameter model of flow through the mitral valve was developed. The model can use minimally-invasive Doppler ultrasound velocity waveforms as model inputs. The model is based on a previously developed model that was developed and calibrated in porcine trials. We have continued the validation of the model in canine trials with the long term goal of developing a clinically useful diagnostic tool in humans. This velocity driven model is a key step toward development of that tool.

KW - Computational fluid dynamics

KW - Congestive heart failure

KW - Insufficiency

KW - Lumped-parameter model

KW - Mitral valve

UR - http://www.scopus.com/inward/record.url?scp=72849118266&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=72849118266&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:72849118266

SN - 9781615671519

VL - 476

SP - 401

EP - 406

BT - 46th Annual Rocky Mountain Bioengineering Symposium and 46th International ISA Biomedical Sciences Instrumentation Symposium 2009

ER -