Egyszeru sebészi módszer az aorta ascendensben elhelyezkedo nagy, lebego thrombus eltávolítására

Translated title of the contribution: A simple surgical method for removing a large floating thrombus from the ascending aorta

Zoltán Szabolcs, Gábor Veres, Tivadar Hüttl, Gábor Bíró, Attila Tóth, Zoltán Szeberin, María Windisch, G. Acsády

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

We report the successful surgical removal of a large floating thrombus from the ascending aorta causing systemic embolization. It was diagnosed by transesophageal echocardiography (TEE), CT scan, aortography and Cardiovascular Magnetic Resonance Imaging (CMR). The free-floating, highly embolic source 2 cm distal to the left coronary sinus was removed from the ascending aorta using a simple surgical technique. Isolated cerebral perfusion with circulatory arrest on normothermia provided a simple and safe access to the thrombus attached to a ruptured atherosclerotic plaque. The patient was discharged on the 7th postoperative day after an uneventful recovery.

Original languageHungarian
Pages (from-to)363-366
Number of pages4
JournalOrvosi Hetilap
Volume148
Issue number8
DOIs
Publication statusPublished - Feb 25 2007

Fingerprint

Aorta
Thrombosis
Aortography
Coronary Sinus
Transesophageal Echocardiography
Atherosclerotic Plaques
Perfusion
Magnetic Resonance Imaging

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Egyszeru sebészi módszer az aorta ascendensben elhelyezkedo nagy, lebego thrombus eltávolítására. / Szabolcs, Zoltán; Veres, Gábor; Hüttl, Tivadar; Bíró, Gábor; Tóth, Attila; Szeberin, Zoltán; Windisch, María; Acsády, G.

In: Orvosi Hetilap, Vol. 148, No. 8, 25.02.2007, p. 363-366.

Research output: Contribution to journalArticle

Szabolcs, Z, Veres, G, Hüttl, T, Bíró, G, Tóth, A, Szeberin, Z, Windisch, M & Acsády, G 2007, 'Egyszeru sebészi módszer az aorta ascendensben elhelyezkedo nagy, lebego thrombus eltávolítására', Orvosi Hetilap, vol. 148, no. 8, pp. 363-366. https://doi.org/10.1556/OH.2007.27975
Szabolcs, Zoltán ; Veres, Gábor ; Hüttl, Tivadar ; Bíró, Gábor ; Tóth, Attila ; Szeberin, Zoltán ; Windisch, María ; Acsády, G. / Egyszeru sebészi módszer az aorta ascendensben elhelyezkedo nagy, lebego thrombus eltávolítására. In: Orvosi Hetilap. 2007 ; Vol. 148, No. 8. pp. 363-366.
@article{7c96f2f0dfb94f7ea09b61639d6487cb,
title = "Egyszeru seb{\'e}szi m{\'o}dszer az aorta ascendensben elhelyezkedo nagy, lebego thrombus elt{\'a}vol{\'i}t{\'a}s{\'a}ra",
abstract = "We report the successful surgical removal of a large floating thrombus from the ascending aorta causing systemic embolization. It was diagnosed by transesophageal echocardiography (TEE), CT scan, aortography and Cardiovascular Magnetic Resonance Imaging (CMR). The free-floating, highly embolic source 2 cm distal to the left coronary sinus was removed from the ascending aorta using a simple surgical technique. Isolated cerebral perfusion with circulatory arrest on normothermia provided a simple and safe access to the thrombus attached to a ruptured atherosclerotic plaque. The patient was discharged on the 7th postoperative day after an uneventful recovery.",
keywords = "Ascending aorta, Free floating thrombus, Isolated cerebral perfusion",
author = "Zolt{\'a}n Szabolcs and G{\'a}bor Veres and Tivadar H{\"u}ttl and G{\'a}bor B{\'i}r{\'o} and Attila T{\'o}th and Zolt{\'a}n Szeberin and Mar{\'i}a Windisch and G. Acs{\'a}dy",
year = "2007",
month = "2",
day = "25",
doi = "10.1556/OH.2007.27975",
language = "Hungarian",
volume = "148",
pages = "363--366",
journal = "Orvosi Hetilap",
issn = "0030-6002",
publisher = "Akademiai Kiado",
number = "8",

}

TY - JOUR

T1 - Egyszeru sebészi módszer az aorta ascendensben elhelyezkedo nagy, lebego thrombus eltávolítására

AU - Szabolcs, Zoltán

AU - Veres, Gábor

AU - Hüttl, Tivadar

AU - Bíró, Gábor

AU - Tóth, Attila

AU - Szeberin, Zoltán

AU - Windisch, María

AU - Acsády, G.

PY - 2007/2/25

Y1 - 2007/2/25

N2 - We report the successful surgical removal of a large floating thrombus from the ascending aorta causing systemic embolization. It was diagnosed by transesophageal echocardiography (TEE), CT scan, aortography and Cardiovascular Magnetic Resonance Imaging (CMR). The free-floating, highly embolic source 2 cm distal to the left coronary sinus was removed from the ascending aorta using a simple surgical technique. Isolated cerebral perfusion with circulatory arrest on normothermia provided a simple and safe access to the thrombus attached to a ruptured atherosclerotic plaque. The patient was discharged on the 7th postoperative day after an uneventful recovery.

AB - We report the successful surgical removal of a large floating thrombus from the ascending aorta causing systemic embolization. It was diagnosed by transesophageal echocardiography (TEE), CT scan, aortography and Cardiovascular Magnetic Resonance Imaging (CMR). The free-floating, highly embolic source 2 cm distal to the left coronary sinus was removed from the ascending aorta using a simple surgical technique. Isolated cerebral perfusion with circulatory arrest on normothermia provided a simple and safe access to the thrombus attached to a ruptured atherosclerotic plaque. The patient was discharged on the 7th postoperative day after an uneventful recovery.

KW - Ascending aorta

KW - Free floating thrombus

KW - Isolated cerebral perfusion

UR - http://www.scopus.com/inward/record.url?scp=34250671960&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34250671960&partnerID=8YFLogxK

U2 - 10.1556/OH.2007.27975

DO - 10.1556/OH.2007.27975

M3 - Article

C2 - 17344160

AN - SCOPUS:34250671960

VL - 148

SP - 363

EP - 366

JO - Orvosi Hetilap

JF - Orvosi Hetilap

SN - 0030-6002

IS - 8