A silicon-based microelectrode array with a microdrive for monitoring brainstem regions of freely moving rats

G. Márton, P. Baracskay, B. Cseri, B. Plósz, G. Juhász, Z. Fekete, A. Pongrácz

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Objective. Exploring neural activity behind synchronization and time locking in brain circuits is one of the most important tasks in neuroscience. Our goal was to design and characterize a microelectrode array (MEA) system specifically for obtaining in vivo extracellular recordings from three deep-brain areas of freely moving rats, simultaneously. The target areas, the deep mesencephalic reticular-, pedunculopontine tegmental-and pontine reticular nuclei are related to the regulation of sleep-wake cycles. Approach. The three targeted nuclei are collinear, therefore a single-shank MEA was designed in order to contact them. The silicon-based device was equipped with 3×4 recording sites, located according to the geometry of the brain regions. Furthermore, a microdrive was developed to allow fine actuation and post-implantation relocation of the probe. The probe was attached to a rigid printed circuit board, which was fastened to the microdrive. A flexible cable was designed in order to provide not only electronic connection between the probe and the amplifier system, but sufficient freedom for the movements of the probe as well. Main results. The microdrive was stable enough to allow precise electrode targeting into the tissue via a single track. The microelectrodes on the probe were suitable for recording neural activity from the three targeted brainstem areas. Significance. The system offers a robust solution to provide long-term interface between an array of precisely defined microelectrodes and deep-brain areas of a behaving rodent. The microdrive allowed us to fine-tune the probe location and easily scan through the regions of interest.

Original languageEnglish
Article number026025
JournalJournal of Neural Engineering
Volume13
Issue number2
DOIs
Publication statusPublished - Feb 29 2016

Fingerprint

Microelectrodes
Silicon
Brain Stem
Rats
Monitoring
Brain
Neurosciences
Rodentia
Sleep
Electrodes
Relocation
Printed circuit boards
Equipment and Supplies
Synchronization
Cables
Tissue
Geometry
Networks (circuits)

Keywords

  • deep brain
  • freely moving
  • microdrive
  • microelectrode array
  • neural probe
  • rat
  • silicon

ASJC Scopus subject areas

  • Biomedical Engineering
  • Cellular and Molecular Neuroscience

Cite this

A silicon-based microelectrode array with a microdrive for monitoring brainstem regions of freely moving rats. / Márton, G.; Baracskay, P.; Cseri, B.; Plósz, B.; Juhász, G.; Fekete, Z.; Pongrácz, A.

In: Journal of Neural Engineering, Vol. 13, No. 2, 026025, 29.02.2016.

Research output: Contribution to journalArticle

Márton, G. ; Baracskay, P. ; Cseri, B. ; Plósz, B. ; Juhász, G. ; Fekete, Z. ; Pongrácz, A. / A silicon-based microelectrode array with a microdrive for monitoring brainstem regions of freely moving rats. In: Journal of Neural Engineering. 2016 ; Vol. 13, No. 2.
@article{5533c854eda446f7b58fd5764eb35a42,
title = "A silicon-based microelectrode array with a microdrive for monitoring brainstem regions of freely moving rats",
abstract = "Objective. Exploring neural activity behind synchronization and time locking in brain circuits is one of the most important tasks in neuroscience. Our goal was to design and characterize a microelectrode array (MEA) system specifically for obtaining in vivo extracellular recordings from three deep-brain areas of freely moving rats, simultaneously. The target areas, the deep mesencephalic reticular-, pedunculopontine tegmental-and pontine reticular nuclei are related to the regulation of sleep-wake cycles. Approach. The three targeted nuclei are collinear, therefore a single-shank MEA was designed in order to contact them. The silicon-based device was equipped with 3×4 recording sites, located according to the geometry of the brain regions. Furthermore, a microdrive was developed to allow fine actuation and post-implantation relocation of the probe. The probe was attached to a rigid printed circuit board, which was fastened to the microdrive. A flexible cable was designed in order to provide not only electronic connection between the probe and the amplifier system, but sufficient freedom for the movements of the probe as well. Main results. The microdrive was stable enough to allow precise electrode targeting into the tissue via a single track. The microelectrodes on the probe were suitable for recording neural activity from the three targeted brainstem areas. Significance. The system offers a robust solution to provide long-term interface between an array of precisely defined microelectrodes and deep-brain areas of a behaving rodent. The microdrive allowed us to fine-tune the probe location and easily scan through the regions of interest.",
keywords = "deep brain, freely moving, microdrive, microelectrode array, neural probe, rat, silicon",
author = "G. M{\'a}rton and P. Baracskay and B. Cseri and B. Pl{\'o}sz and G. Juh{\'a}sz and Z. Fekete and A. Pongr{\'a}cz",
year = "2016",
month = "2",
day = "29",
doi = "10.1088/1741-2560/13/2/026025",
language = "English",
volume = "13",
journal = "Journal of Neural Engineering",
issn = "1741-2560",
publisher = "IOP Publishing Ltd.",
number = "2",

}

TY - JOUR

T1 - A silicon-based microelectrode array with a microdrive for monitoring brainstem regions of freely moving rats

AU - Márton, G.

AU - Baracskay, P.

AU - Cseri, B.

AU - Plósz, B.

AU - Juhász, G.

AU - Fekete, Z.

AU - Pongrácz, A.

PY - 2016/2/29

Y1 - 2016/2/29

N2 - Objective. Exploring neural activity behind synchronization and time locking in brain circuits is one of the most important tasks in neuroscience. Our goal was to design and characterize a microelectrode array (MEA) system specifically for obtaining in vivo extracellular recordings from three deep-brain areas of freely moving rats, simultaneously. The target areas, the deep mesencephalic reticular-, pedunculopontine tegmental-and pontine reticular nuclei are related to the regulation of sleep-wake cycles. Approach. The three targeted nuclei are collinear, therefore a single-shank MEA was designed in order to contact them. The silicon-based device was equipped with 3×4 recording sites, located according to the geometry of the brain regions. Furthermore, a microdrive was developed to allow fine actuation and post-implantation relocation of the probe. The probe was attached to a rigid printed circuit board, which was fastened to the microdrive. A flexible cable was designed in order to provide not only electronic connection between the probe and the amplifier system, but sufficient freedom for the movements of the probe as well. Main results. The microdrive was stable enough to allow precise electrode targeting into the tissue via a single track. The microelectrodes on the probe were suitable for recording neural activity from the three targeted brainstem areas. Significance. The system offers a robust solution to provide long-term interface between an array of precisely defined microelectrodes and deep-brain areas of a behaving rodent. The microdrive allowed us to fine-tune the probe location and easily scan through the regions of interest.

AB - Objective. Exploring neural activity behind synchronization and time locking in brain circuits is one of the most important tasks in neuroscience. Our goal was to design and characterize a microelectrode array (MEA) system specifically for obtaining in vivo extracellular recordings from three deep-brain areas of freely moving rats, simultaneously. The target areas, the deep mesencephalic reticular-, pedunculopontine tegmental-and pontine reticular nuclei are related to the regulation of sleep-wake cycles. Approach. The three targeted nuclei are collinear, therefore a single-shank MEA was designed in order to contact them. The silicon-based device was equipped with 3×4 recording sites, located according to the geometry of the brain regions. Furthermore, a microdrive was developed to allow fine actuation and post-implantation relocation of the probe. The probe was attached to a rigid printed circuit board, which was fastened to the microdrive. A flexible cable was designed in order to provide not only electronic connection between the probe and the amplifier system, but sufficient freedom for the movements of the probe as well. Main results. The microdrive was stable enough to allow precise electrode targeting into the tissue via a single track. The microelectrodes on the probe were suitable for recording neural activity from the three targeted brainstem areas. Significance. The system offers a robust solution to provide long-term interface between an array of precisely defined microelectrodes and deep-brain areas of a behaving rodent. The microdrive allowed us to fine-tune the probe location and easily scan through the regions of interest.

KW - deep brain

KW - freely moving

KW - microdrive

KW - microelectrode array

KW - neural probe

KW - rat

KW - silicon

UR - http://www.scopus.com/inward/record.url?scp=84962339464&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84962339464&partnerID=8YFLogxK

U2 - 10.1088/1741-2560/13/2/026025

DO - 10.1088/1741-2560/13/2/026025

M3 - Article

VL - 13

JO - Journal of Neural Engineering

JF - Journal of Neural Engineering

SN - 1741-2560

IS - 2

M1 - 026025

ER -