Treatment of juxta-articular comminuted fractures with dislocated fragments of long bones are difficult for intramedullar interlocking nails. The question is can the results be improved by a modified interlocking nail. The Synthes UHN was prepared by 7 additionally bore holes displaced for 90 degrees. This modified implant contains a total of 12 interlocking points in different directions. The biomechanical testing showed a maximal reduction of the bending strength of 35 % for the modified nail. It seems to be dependent from the orientation of the bending stress. The modified nail with unreamed technique was implanted in the tibial bone of the sheep. This was carried out after segmental osteotomy with/without an additionally interlocking third fragment. 8 weeks postoperatively in 75 % of all cases a consolidation in the sense of fracture healing could be seen. The none used bore holes of the modified nail were penetrated with active osteogenetic tissue. Our results should be compared with the findings of the bone conduction chamber. The aplicability of our model for experimental osteological studies will be discussed.

Original languageGerman
Pages (from-to)164-174
Number of pages11
JournalOsteologie
Volume15
Issue number3
DOIs
Publication statusPublished - Sep 2006

Fingerprint

Nails
Tibia
Sheep
Bone Conduction
Comminuted Fractures
Bone and Bones
Fracture Healing
Osteotomy
Theoretical Models
Joints
Therapeutics

Keywords

  • Biomechanic
  • Interlocking nail
  • Segmental osteosyntesis
  • Tibial bone of the sheep

ASJC Scopus subject areas

  • Medicine(all)
  • Surgery

Cite this

Ein modifizierter marknagel im tierexperiment (I) : Beschreibung, erster biomechanischer test und implantation in die schaftibia. / Höcherl, Eduard F J; Soltay, P.; Hamar, J.; Wolf, K.; Pfister, C.

In: Osteologie, Vol. 15, No. 3, 09.2006, p. 164-174.

Research output: Contribution to journalArticle

Höcherl, Eduard F J ; Soltay, P. ; Hamar, J. ; Wolf, K. ; Pfister, C. / Ein modifizierter marknagel im tierexperiment (I) : Beschreibung, erster biomechanischer test und implantation in die schaftibia. In: Osteologie. 2006 ; Vol. 15, No. 3. pp. 164-174.
@article{25f3186ad0774c248800bf8142ccd6d0,
title = "Ein modifizierter marknagel im tierexperiment (I): Beschreibung, erster biomechanischer test und implantation in die schaftibia",
abstract = "Treatment of juxta-articular comminuted fractures with dislocated fragments of long bones are difficult for intramedullar interlocking nails. The question is can the results be improved by a modified interlocking nail. The Synthes UHN was prepared by 7 additionally bore holes displaced for 90 degrees. This modified implant contains a total of 12 interlocking points in different directions. The biomechanical testing showed a maximal reduction of the bending strength of 35 {\%} for the modified nail. It seems to be dependent from the orientation of the bending stress. The modified nail with unreamed technique was implanted in the tibial bone of the sheep. This was carried out after segmental osteotomy with/without an additionally interlocking third fragment. 8 weeks postoperatively in 75 {\%} of all cases a consolidation in the sense of fracture healing could be seen. The none used bore holes of the modified nail were penetrated with active osteogenetic tissue. Our results should be compared with the findings of the bone conduction chamber. The aplicability of our model for experimental osteological studies will be discussed.",
keywords = "Biomechanic, Interlocking nail, Segmental osteosyntesis, Tibial bone of the sheep",
author = "H{\"o}cherl, {Eduard F J} and P. Soltay and J. Hamar and K. Wolf and C. Pfister",
year = "2006",
month = "9",
doi = "10.1024/1019-1291.15.3.164",
language = "German",
volume = "15",
pages = "164--174",
journal = "Osteologie",
issn = "1019-1291",
publisher = "Verlag Hans Huber",
number = "3",

}

TY - JOUR

T1 - Ein modifizierter marknagel im tierexperiment (I)

T2 - Beschreibung, erster biomechanischer test und implantation in die schaftibia

AU - Höcherl, Eduard F J

AU - Soltay, P.

AU - Hamar, J.

AU - Wolf, K.

AU - Pfister, C.

PY - 2006/9

Y1 - 2006/9

N2 - Treatment of juxta-articular comminuted fractures with dislocated fragments of long bones are difficult for intramedullar interlocking nails. The question is can the results be improved by a modified interlocking nail. The Synthes UHN was prepared by 7 additionally bore holes displaced for 90 degrees. This modified implant contains a total of 12 interlocking points in different directions. The biomechanical testing showed a maximal reduction of the bending strength of 35 % for the modified nail. It seems to be dependent from the orientation of the bending stress. The modified nail with unreamed technique was implanted in the tibial bone of the sheep. This was carried out after segmental osteotomy with/without an additionally interlocking third fragment. 8 weeks postoperatively in 75 % of all cases a consolidation in the sense of fracture healing could be seen. The none used bore holes of the modified nail were penetrated with active osteogenetic tissue. Our results should be compared with the findings of the bone conduction chamber. The aplicability of our model for experimental osteological studies will be discussed.

AB - Treatment of juxta-articular comminuted fractures with dislocated fragments of long bones are difficult for intramedullar interlocking nails. The question is can the results be improved by a modified interlocking nail. The Synthes UHN was prepared by 7 additionally bore holes displaced for 90 degrees. This modified implant contains a total of 12 interlocking points in different directions. The biomechanical testing showed a maximal reduction of the bending strength of 35 % for the modified nail. It seems to be dependent from the orientation of the bending stress. The modified nail with unreamed technique was implanted in the tibial bone of the sheep. This was carried out after segmental osteotomy with/without an additionally interlocking third fragment. 8 weeks postoperatively in 75 % of all cases a consolidation in the sense of fracture healing could be seen. The none used bore holes of the modified nail were penetrated with active osteogenetic tissue. Our results should be compared with the findings of the bone conduction chamber. The aplicability of our model for experimental osteological studies will be discussed.

KW - Biomechanic

KW - Interlocking nail

KW - Segmental osteosyntesis

KW - Tibial bone of the sheep

UR - http://www.scopus.com/inward/record.url?scp=33845347539&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845347539&partnerID=8YFLogxK

U2 - 10.1024/1019-1291.15.3.164

DO - 10.1024/1019-1291.15.3.164

M3 - Article

VL - 15

SP - 164

EP - 174

JO - Osteologie

JF - Osteologie

SN - 1019-1291

IS - 3

ER -