A distorted field cylindrical mirror electron spectrometer. I. Calculation of the analyzer

Dezsö Varga, A. Kövér, L. Kövér, László Redler

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

A new "box" type cylindrical mirror electrostatic analyzer (CMA) with second order focusing properties is presented. The effect of the fringing field was taken into consideration in the design, resulting in some advantage (e.g. better dispersion) compared to the classical CMA.

Original languageEnglish
Pages (from-to)393-395
Number of pages3
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume238
Issue number2-3
DOIs
Publication statusPublished - Aug 1 1985

Fingerprint

Spectrometers
Electrostatics
analyzers
Mirrors
spectrometers
electrostatics
mirrors
Electrons
boxes
electrons

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics
  • Engineering(all)

Cite this

@article{fbf274795366481fac529a9630bb4cc6,
title = "A distorted field cylindrical mirror electron spectrometer. I. Calculation of the analyzer",
abstract = "A new {"}box{"} type cylindrical mirror electrostatic analyzer (CMA) with second order focusing properties is presented. The effect of the fringing field was taken into consideration in the design, resulting in some advantage (e.g. better dispersion) compared to the classical CMA.",
author = "Dezs{\"o} Varga and A. K{\"o}v{\'e}r and L. K{\"o}v{\'e}r and L{\'a}szl{\'o} Redler",
year = "1985",
month = "8",
day = "1",
doi = "10.1016/0168-9002(85)90476-0",
language = "English",
volume = "238",
pages = "393--395",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",
number = "2-3",

}

TY - JOUR

T1 - A distorted field cylindrical mirror electron spectrometer. I. Calculation of the analyzer

AU - Varga, Dezsö

AU - Kövér, A.

AU - Kövér, L.

AU - Redler, László

PY - 1985/8/1

Y1 - 1985/8/1

N2 - A new "box" type cylindrical mirror electrostatic analyzer (CMA) with second order focusing properties is presented. The effect of the fringing field was taken into consideration in the design, resulting in some advantage (e.g. better dispersion) compared to the classical CMA.

AB - A new "box" type cylindrical mirror electrostatic analyzer (CMA) with second order focusing properties is presented. The effect of the fringing field was taken into consideration in the design, resulting in some advantage (e.g. better dispersion) compared to the classical CMA.

UR - http://www.scopus.com/inward/record.url?scp=0022110787&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022110787&partnerID=8YFLogxK

U2 - 10.1016/0168-9002(85)90476-0

DO - 10.1016/0168-9002(85)90476-0

M3 - Article

VL - 238

SP - 393

EP - 395

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

IS - 2-3

ER -