A dispersive liquid-liquid microextraction procedure for UV-Vis spectrophotometric determination of chromium(vi) in water samples

Michal Alexovič, I. Balogh, Jana Škrlíková, Vasil Andruch

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

A novel and simple procedure for chromium determination has been developed. The method is based on the reaction of chromium(vi) with dimethylindocarbocyanine dye reagent (DIC) in an acidic medium and in the presence of chloride ions, followed by dispersive liquid-liquid microextraction of the formed ion associate into the organic phase containing a mixture of toluene (extraction solvent), carbon tetrachloride (auxiliary solvent) and acetonitrile (dispersive solvent) in a ratio of 1:1:2 (v:v:v) and subsequent UV-VIS detection at 550 nm. The calibration plot was linear in the range 0.10-0.52 mg L -1 of chromium. The limit of detection calculated based on 3s and limit of quantification calculated based on 10s is 0.03 mg L -1 and 0.07 mg L -1. The method was applied to the determination of chromium(vi) in spiked water samples.

Original languageEnglish
Pages (from-to)1410-1414
Number of pages5
JournalAnalytical Methods
Volume4
Issue number5
DOIs
Publication statusPublished - May 2012

Fingerprint

Chromium
Water
Liquids
Ions
Dacarbazine
Carbon tetrachloride
Carbon Tetrachloride
Toluene
Solvent extraction
Acetonitrile
Chlorides
Coloring Agents
Dyes
Calibration

ASJC Scopus subject areas

  • Analytical Chemistry
  • Engineering(all)
  • Chemical Engineering(all)

Cite this

A dispersive liquid-liquid microextraction procedure for UV-Vis spectrophotometric determination of chromium(vi) in water samples. / Alexovič, Michal; Balogh, I.; Škrlíková, Jana; Andruch, Vasil.

In: Analytical Methods, Vol. 4, No. 5, 05.2012, p. 1410-1414.

Research output: Contribution to journalArticle

@article{9107a432bc1946569c1daeb5eb3fb738,
title = "A dispersive liquid-liquid microextraction procedure for UV-Vis spectrophotometric determination of chromium(vi) in water samples",
abstract = "A novel and simple procedure for chromium determination has been developed. The method is based on the reaction of chromium(vi) with dimethylindocarbocyanine dye reagent (DIC) in an acidic medium and in the presence of chloride ions, followed by dispersive liquid-liquid microextraction of the formed ion associate into the organic phase containing a mixture of toluene (extraction solvent), carbon tetrachloride (auxiliary solvent) and acetonitrile (dispersive solvent) in a ratio of 1:1:2 (v:v:v) and subsequent UV-VIS detection at 550 nm. The calibration plot was linear in the range 0.10-0.52 mg L -1 of chromium. The limit of detection calculated based on 3s and limit of quantification calculated based on 10s is 0.03 mg L -1 and 0.07 mg L -1. The method was applied to the determination of chromium(vi) in spiked water samples.",
author = "Michal Alexovič and I. Balogh and Jana Škrl{\'i}kov{\'a} and Vasil Andruch",
year = "2012",
month = "5",
doi = "10.1039/c2ay25133g",
language = "English",
volume = "4",
pages = "1410--1414",
journal = "Analytical Methods",
issn = "1759-9660",
publisher = "Royal Society of Chemistry",
number = "5",

}

TY - JOUR

T1 - A dispersive liquid-liquid microextraction procedure for UV-Vis spectrophotometric determination of chromium(vi) in water samples

AU - Alexovič, Michal

AU - Balogh, I.

AU - Škrlíková, Jana

AU - Andruch, Vasil

PY - 2012/5

Y1 - 2012/5

N2 - A novel and simple procedure for chromium determination has been developed. The method is based on the reaction of chromium(vi) with dimethylindocarbocyanine dye reagent (DIC) in an acidic medium and in the presence of chloride ions, followed by dispersive liquid-liquid microextraction of the formed ion associate into the organic phase containing a mixture of toluene (extraction solvent), carbon tetrachloride (auxiliary solvent) and acetonitrile (dispersive solvent) in a ratio of 1:1:2 (v:v:v) and subsequent UV-VIS detection at 550 nm. The calibration plot was linear in the range 0.10-0.52 mg L -1 of chromium. The limit of detection calculated based on 3s and limit of quantification calculated based on 10s is 0.03 mg L -1 and 0.07 mg L -1. The method was applied to the determination of chromium(vi) in spiked water samples.

AB - A novel and simple procedure for chromium determination has been developed. The method is based on the reaction of chromium(vi) with dimethylindocarbocyanine dye reagent (DIC) in an acidic medium and in the presence of chloride ions, followed by dispersive liquid-liquid microextraction of the formed ion associate into the organic phase containing a mixture of toluene (extraction solvent), carbon tetrachloride (auxiliary solvent) and acetonitrile (dispersive solvent) in a ratio of 1:1:2 (v:v:v) and subsequent UV-VIS detection at 550 nm. The calibration plot was linear in the range 0.10-0.52 mg L -1 of chromium. The limit of detection calculated based on 3s and limit of quantification calculated based on 10s is 0.03 mg L -1 and 0.07 mg L -1. The method was applied to the determination of chromium(vi) in spiked water samples.

UR - http://www.scopus.com/inward/record.url?scp=84860737787&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84860737787&partnerID=8YFLogxK

U2 - 10.1039/c2ay25133g

DO - 10.1039/c2ay25133g

M3 - Article

AN - SCOPUS:84860737787

VL - 4

SP - 1410

EP - 1414

JO - Analytical Methods

JF - Analytical Methods

SN - 1759-9660

IS - 5

ER -