Uniplant SP fogászati ideiglenes implantátumok laboratóriumi terheléses vizsgálata.

Translated title of the contribution: A biomechanical study of Uniplant SP temporary dental implants: loading under laboratory conditions

Attila Szucs, Lajos Borbás, Tamás Divinyi, J. Barabás

Research output: Contribution to journalArticle

Abstract

The mechanical strength parameters of Uniplant SP temporary implants were investigated. In clinical practice temporary implants are used to provide the patient with a fixed temporary restoration. Temporary implants are one-part implants small in diameter, and by design they have excellent primary stability. The temporary fixtures are usually placed simultaneously with the final implants. They positioned between the final implants. Due to their good stability they can immediately be loaded. They are usually expected to function till the final implants are ready for loading and when no longer needed, the temporary implants are removed. The abutment that carries the prosthetic components is manufactured in one piece with the implant, connected to it with a narrower neck portion. This neck part might easily fracture in the first instance when the abutment is bent to make abutments parallel in order to fabricate the temporary prosthetic device and in a second instance when temporary implants are removed. In the present study the mechanical properties of the cervical part were studied in a custom-designed device. Based on the results of the loading studies recommendations were made to modify the current shape of the implant. With minimal modification of the implant design and lengthening the implant neck risk of fracture can be significantly reduced.

Original languageHungarian
Pages (from-to)53-58
Number of pages6
JournalFogorvosi szemle
Volume103
Issue number2
Publication statusPublished - Jun 2010

Fingerprint

Dental Implants
Neck
Equipment and Supplies

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Uniplant SP fogászati ideiglenes implantátumok laboratóriumi terheléses vizsgálata. / Szucs, Attila; Borbás, Lajos; Divinyi, Tamás; Barabás, J.

In: Fogorvosi szemle, Vol. 103, No. 2, 06.2010, p. 53-58.

Research output: Contribution to journalArticle

Szucs, Attila ; Borbás, Lajos ; Divinyi, Tamás ; Barabás, J. / Uniplant SP fogászati ideiglenes implantátumok laboratóriumi terheléses vizsgálata. In: Fogorvosi szemle. 2010 ; Vol. 103, No. 2. pp. 53-58.
@article{e89401ae00184afda552d1b1a0e6de69,
title = "Uniplant SP fog{\'a}szati ideiglenes implant{\'a}tumok laborat{\'o}riumi terhel{\'e}ses vizsg{\'a}lata.",
abstract = "The mechanical strength parameters of Uniplant SP temporary implants were investigated. In clinical practice temporary implants are used to provide the patient with a fixed temporary restoration. Temporary implants are one-part implants small in diameter, and by design they have excellent primary stability. The temporary fixtures are usually placed simultaneously with the final implants. They positioned between the final implants. Due to their good stability they can immediately be loaded. They are usually expected to function till the final implants are ready for loading and when no longer needed, the temporary implants are removed. The abutment that carries the prosthetic components is manufactured in one piece with the implant, connected to it with a narrower neck portion. This neck part might easily fracture in the first instance when the abutment is bent to make abutments parallel in order to fabricate the temporary prosthetic device and in a second instance when temporary implants are removed. In the present study the mechanical properties of the cervical part were studied in a custom-designed device. Based on the results of the loading studies recommendations were made to modify the current shape of the implant. With minimal modification of the implant design and lengthening the implant neck risk of fracture can be significantly reduced.",
author = "Attila Szucs and Lajos Borb{\'a}s and Tam{\'a}s Divinyi and J. Barab{\'a}s",
year = "2010",
month = "6",
language = "Hungarian",
volume = "103",
pages = "53--58",
journal = "Fogorvosi szemle",
issn = "0015-5314",
publisher = "Ifjusagi Lapkiado Vallalat",
number = "2",

}

TY - JOUR

T1 - Uniplant SP fogászati ideiglenes implantátumok laboratóriumi terheléses vizsgálata.

AU - Szucs, Attila

AU - Borbás, Lajos

AU - Divinyi, Tamás

AU - Barabás, J.

PY - 2010/6

Y1 - 2010/6

N2 - The mechanical strength parameters of Uniplant SP temporary implants were investigated. In clinical practice temporary implants are used to provide the patient with a fixed temporary restoration. Temporary implants are one-part implants small in diameter, and by design they have excellent primary stability. The temporary fixtures are usually placed simultaneously with the final implants. They positioned between the final implants. Due to their good stability they can immediately be loaded. They are usually expected to function till the final implants are ready for loading and when no longer needed, the temporary implants are removed. The abutment that carries the prosthetic components is manufactured in one piece with the implant, connected to it with a narrower neck portion. This neck part might easily fracture in the first instance when the abutment is bent to make abutments parallel in order to fabricate the temporary prosthetic device and in a second instance when temporary implants are removed. In the present study the mechanical properties of the cervical part were studied in a custom-designed device. Based on the results of the loading studies recommendations were made to modify the current shape of the implant. With minimal modification of the implant design and lengthening the implant neck risk of fracture can be significantly reduced.

AB - The mechanical strength parameters of Uniplant SP temporary implants were investigated. In clinical practice temporary implants are used to provide the patient with a fixed temporary restoration. Temporary implants are one-part implants small in diameter, and by design they have excellent primary stability. The temporary fixtures are usually placed simultaneously with the final implants. They positioned between the final implants. Due to their good stability they can immediately be loaded. They are usually expected to function till the final implants are ready for loading and when no longer needed, the temporary implants are removed. The abutment that carries the prosthetic components is manufactured in one piece with the implant, connected to it with a narrower neck portion. This neck part might easily fracture in the first instance when the abutment is bent to make abutments parallel in order to fabricate the temporary prosthetic device and in a second instance when temporary implants are removed. In the present study the mechanical properties of the cervical part were studied in a custom-designed device. Based on the results of the loading studies recommendations were made to modify the current shape of the implant. With minimal modification of the implant design and lengthening the implant neck risk of fracture can be significantly reduced.

UR - http://www.scopus.com/inward/record.url?scp=77955968468&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77955968468&partnerID=8YFLogxK

M3 - Article

C2 - 20672753

AN - SCOPUS:77955968468

VL - 103

SP - 53

EP - 58

JO - Fogorvosi szemle

JF - Fogorvosi szemle

SN - 0015-5314

IS - 2

ER -