3DVIEWNIX-AVS

A software package for the separate visualization of arteries and veins in CE-MRA images

Tianhu Lei, Jayaram K. Udupa, Dewey Odhner, L. Nyúl, Punam K. Saha

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Our earlier study developed a computerized method, based on fuzzy connected object delineation principles and algorithms, for artery and vein separation in contrast enhanced Magnetic Resonance Angiography (CE-MRA) images. This paper reports its current development - a software package - for routine clinical use. The software package, termed 3DVIEWNIX-AVS, consists of the following major operational parts: (1) converting data from DICOM3 to 3DVIEWNIX format, (2) previewing slices and creating VOI and MIP Shell, (3) segmenting vessel, (4) separating artery and vein, (5) shell rendering vascular structures and creating animations. This package has been applied to EPIX Medical Inc's CE-MRA data (AngioMark MS-325). One hundred and thirty-five original CE-MRA data sets (of 52 patients) from 6 hospitals have been processed. In all case studies, unified parameter settings produce correct artery-vein separation. The current package is running on a Pentium PC under Linux and the total computation time per study is about 3 min. The strengths of this software package are (1) minimal user interaction, (2) minimal anatomic knowledge requirements on human vascular system, (3) clinically required speed, (4) free entry to any operational stages, (5) reproducible, reliable, high quality of results, and (6) cost effective computer implementation. To date, it seems to be the only software package (using an image processing approach) available for artery and vein separation of the human vascular system for routine use in a clinical setting.

Original languageEnglish
Pages (from-to)351-362
Number of pages12
JournalComputerized Medical Imaging and Graphics
Volume27
Issue number5
DOIs
Publication statusPublished - Sep 2003

Fingerprint

Angiography
Magnetic Resonance Angiography
Magnetic resonance
Software packages
Veins
Software
Visualization
Arteries
Blood Vessels
Animation
Running
Image processing
Costs and Cost Analysis
Costs

Keywords

  • Artery-vein separation
  • Contrast enhanced magnetic resonance angiography
  • Fuzzy connectedness
  • Image segmentation
  • Visualization systems

ASJC Scopus subject areas

  • Computer Science Applications
  • Radiology Nuclear Medicine and imaging

Cite this

3DVIEWNIX-AVS : A software package for the separate visualization of arteries and veins in CE-MRA images. / Lei, Tianhu; Udupa, Jayaram K.; Odhner, Dewey; Nyúl, L.; Saha, Punam K.

In: Computerized Medical Imaging and Graphics, Vol. 27, No. 5, 09.2003, p. 351-362.

Research output: Contribution to journalArticle

Lei, Tianhu ; Udupa, Jayaram K. ; Odhner, Dewey ; Nyúl, L. ; Saha, Punam K. / 3DVIEWNIX-AVS : A software package for the separate visualization of arteries and veins in CE-MRA images. In: Computerized Medical Imaging and Graphics. 2003 ; Vol. 27, No. 5. pp. 351-362.
@article{5649ba1536b04a18b608a5fb4d90fa0e,
title = "3DVIEWNIX-AVS: A software package for the separate visualization of arteries and veins in CE-MRA images",
abstract = "Our earlier study developed a computerized method, based on fuzzy connected object delineation principles and algorithms, for artery and vein separation in contrast enhanced Magnetic Resonance Angiography (CE-MRA) images. This paper reports its current development - a software package - for routine clinical use. The software package, termed 3DVIEWNIX-AVS, consists of the following major operational parts: (1) converting data from DICOM3 to 3DVIEWNIX format, (2) previewing slices and creating VOI and MIP Shell, (3) segmenting vessel, (4) separating artery and vein, (5) shell rendering vascular structures and creating animations. This package has been applied to EPIX Medical Inc's CE-MRA data (AngioMark MS-325). One hundred and thirty-five original CE-MRA data sets (of 52 patients) from 6 hospitals have been processed. In all case studies, unified parameter settings produce correct artery-vein separation. The current package is running on a Pentium PC under Linux and the total computation time per study is about 3 min. The strengths of this software package are (1) minimal user interaction, (2) minimal anatomic knowledge requirements on human vascular system, (3) clinically required speed, (4) free entry to any operational stages, (5) reproducible, reliable, high quality of results, and (6) cost effective computer implementation. To date, it seems to be the only software package (using an image processing approach) available for artery and vein separation of the human vascular system for routine use in a clinical setting.",
keywords = "Artery-vein separation, Contrast enhanced magnetic resonance angiography, Fuzzy connectedness, Image segmentation, Visualization systems",
author = "Tianhu Lei and Udupa, {Jayaram K.} and Dewey Odhner and L. Ny{\'u}l and Saha, {Punam K.}",
year = "2003",
month = "9",
doi = "10.1016/S0895-6111(03)00029-6",
language = "English",
volume = "27",
pages = "351--362",
journal = "Computerized Medical Imaging and Graphics",
issn = "0895-6111",
publisher = "Elsevier Limited",
number = "5",

}

TY - JOUR

T1 - 3DVIEWNIX-AVS

T2 - A software package for the separate visualization of arteries and veins in CE-MRA images

AU - Lei, Tianhu

AU - Udupa, Jayaram K.

AU - Odhner, Dewey

AU - Nyúl, L.

AU - Saha, Punam K.

PY - 2003/9

Y1 - 2003/9

N2 - Our earlier study developed a computerized method, based on fuzzy connected object delineation principles and algorithms, for artery and vein separation in contrast enhanced Magnetic Resonance Angiography (CE-MRA) images. This paper reports its current development - a software package - for routine clinical use. The software package, termed 3DVIEWNIX-AVS, consists of the following major operational parts: (1) converting data from DICOM3 to 3DVIEWNIX format, (2) previewing slices and creating VOI and MIP Shell, (3) segmenting vessel, (4) separating artery and vein, (5) shell rendering vascular structures and creating animations. This package has been applied to EPIX Medical Inc's CE-MRA data (AngioMark MS-325). One hundred and thirty-five original CE-MRA data sets (of 52 patients) from 6 hospitals have been processed. In all case studies, unified parameter settings produce correct artery-vein separation. The current package is running on a Pentium PC under Linux and the total computation time per study is about 3 min. The strengths of this software package are (1) minimal user interaction, (2) minimal anatomic knowledge requirements on human vascular system, (3) clinically required speed, (4) free entry to any operational stages, (5) reproducible, reliable, high quality of results, and (6) cost effective computer implementation. To date, it seems to be the only software package (using an image processing approach) available for artery and vein separation of the human vascular system for routine use in a clinical setting.

AB - Our earlier study developed a computerized method, based on fuzzy connected object delineation principles and algorithms, for artery and vein separation in contrast enhanced Magnetic Resonance Angiography (CE-MRA) images. This paper reports its current development - a software package - for routine clinical use. The software package, termed 3DVIEWNIX-AVS, consists of the following major operational parts: (1) converting data from DICOM3 to 3DVIEWNIX format, (2) previewing slices and creating VOI and MIP Shell, (3) segmenting vessel, (4) separating artery and vein, (5) shell rendering vascular structures and creating animations. This package has been applied to EPIX Medical Inc's CE-MRA data (AngioMark MS-325). One hundred and thirty-five original CE-MRA data sets (of 52 patients) from 6 hospitals have been processed. In all case studies, unified parameter settings produce correct artery-vein separation. The current package is running on a Pentium PC under Linux and the total computation time per study is about 3 min. The strengths of this software package are (1) minimal user interaction, (2) minimal anatomic knowledge requirements on human vascular system, (3) clinically required speed, (4) free entry to any operational stages, (5) reproducible, reliable, high quality of results, and (6) cost effective computer implementation. To date, it seems to be the only software package (using an image processing approach) available for artery and vein separation of the human vascular system for routine use in a clinical setting.

KW - Artery-vein separation

KW - Contrast enhanced magnetic resonance angiography

KW - Fuzzy connectedness

KW - Image segmentation

KW - Visualization systems

UR - http://www.scopus.com/inward/record.url?scp=0038122922&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0038122922&partnerID=8YFLogxK

U2 - 10.1016/S0895-6111(03)00029-6

DO - 10.1016/S0895-6111(03)00029-6

M3 - Article

VL - 27

SP - 351

EP - 362

JO - Computerized Medical Imaging and Graphics

JF - Computerized Medical Imaging and Graphics

SN - 0895-6111

IS - 5

ER -