2D ESR image reconstruction from 1D projections using the modulated field gradient method

T. Páli, L. Sass, L. I. Horvat, B. Ebert

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

A method for the reconstruction of 2D ESR images from 1 D projections which is based on the modulated field gradient method has been explored. The 2D distribution of spin-labeled stearic acid in oriented and unoriented dimyristoyl phosphatidylcholine multilayers on a flat quartz support was determined. Such samples are potentially useful for the determination of lipid lateral diffusion in oriented multilayers by monitoring the spreading of a sharp concentration profile in one or two dimensions. The limitations of the method are discussed and the improvements which are needed for dynamic measurements are outlined.

Original languageEnglish
Pages (from-to)338-345
Number of pages8
JournalJournal of Magnetic Resonance (1969)
Volume86
Issue number2
DOIs
Publication statusPublished - Feb 1 1990

Fingerprint

image reconstruction
projection
gradients
lipids
quartz
acids
profiles

Cite this

2D ESR image reconstruction from 1D projections using the modulated field gradient method. / Páli, T.; Sass, L.; Horvat, L. I.; Ebert, B.

In: Journal of Magnetic Resonance (1969), Vol. 86, No. 2, 01.02.1990, p. 338-345.

Research output: Contribution to journalArticle

@article{87f4c0453504403e8d26a5663069b13e,
title = "2D ESR image reconstruction from 1D projections using the modulated field gradient method",
abstract = "A method for the reconstruction of 2D ESR images from 1 D projections which is based on the modulated field gradient method has been explored. The 2D distribution of spin-labeled stearic acid in oriented and unoriented dimyristoyl phosphatidylcholine multilayers on a flat quartz support was determined. Such samples are potentially useful for the determination of lipid lateral diffusion in oriented multilayers by monitoring the spreading of a sharp concentration profile in one or two dimensions. The limitations of the method are discussed and the improvements which are needed for dynamic measurements are outlined.",
author = "T. P{\'a}li and L. Sass and Horvat, {L. I.} and B. Ebert",
year = "1990",
month = "2",
day = "1",
doi = "10.1016/0022-2364(90)90264-A",
language = "English",
volume = "86",
pages = "338--345",
journal = "Journal of Magnetic Resonance (1969)",
issn = "0022-2364",
publisher = "Academic Press Inc.",
number = "2",

}

TY - JOUR

T1 - 2D ESR image reconstruction from 1D projections using the modulated field gradient method

AU - Páli, T.

AU - Sass, L.

AU - Horvat, L. I.

AU - Ebert, B.

PY - 1990/2/1

Y1 - 1990/2/1

N2 - A method for the reconstruction of 2D ESR images from 1 D projections which is based on the modulated field gradient method has been explored. The 2D distribution of spin-labeled stearic acid in oriented and unoriented dimyristoyl phosphatidylcholine multilayers on a flat quartz support was determined. Such samples are potentially useful for the determination of lipid lateral diffusion in oriented multilayers by monitoring the spreading of a sharp concentration profile in one or two dimensions. The limitations of the method are discussed and the improvements which are needed for dynamic measurements are outlined.

AB - A method for the reconstruction of 2D ESR images from 1 D projections which is based on the modulated field gradient method has been explored. The 2D distribution of spin-labeled stearic acid in oriented and unoriented dimyristoyl phosphatidylcholine multilayers on a flat quartz support was determined. Such samples are potentially useful for the determination of lipid lateral diffusion in oriented multilayers by monitoring the spreading of a sharp concentration profile in one or two dimensions. The limitations of the method are discussed and the improvements which are needed for dynamic measurements are outlined.

UR - http://www.scopus.com/inward/record.url?scp=38249018661&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=38249018661&partnerID=8YFLogxK

U2 - 10.1016/0022-2364(90)90264-A

DO - 10.1016/0022-2364(90)90264-A

M3 - Article

VL - 86

SP - 338

EP - 345

JO - Journal of Magnetic Resonance (1969)

JF - Journal of Magnetic Resonance (1969)

SN - 0022-2364

IS - 2

ER -